Flat fan spray nozzles
Remkom LLC has manufactured flat fan spray nozzles for agricultural boom sprayers since 2003. The range includes standard CT-series and air-induction TP-series nozzles. More than 3.5 million nozzles have been produced to date.
The nozzles are made of chemically resistant engineering plastic — polyoxymethylene (POM). Colour coding complies with ISO 10625, and connection dimensions comply with ISO 10626.
They produce a flat fan spray pattern with an elliptical footprint on the treated surface.
Remkom nozzles have a spray angle of 110 ± 5°, a recommended spacing of 0.5 m along the boom and a recommended operating height of 0.5–0.7 m above the target.

Application Rates, L/ha
| Code | Image | ![]() | ![]() | 8 km/h | 9 km/h | 10 km/h | 11 km/h | 12 km/h | 14 km/h | 16 km/h |
|---|---|---|---|---|---|---|---|---|---|---|
| CT 110.03 | ![]() |
2 | 0,98 | 147 | 131 | 118 | 107 | 98 | 84 | 73 |
| 3 | 1,20 | 180 | 160 | 144 | 131 | 120 | 103 | 90 | ||
| 4 | 1,39 | 208 | 185 | 166 | 151 | 139 | 119 | 104 | ||
| 5 | 1,55 | 232 | 207 | 186 | 169 | 155 | 133 | 116 | ||
| 6 | 1,70 | 255 | 226 | 204 | 185 | 170 | 145 | 127 | ||
| 7 | 1,83 | 275 | 244 | 220 | 200 | 183 | 157 | 137 | ||
| 8 | 1,96 | 294 | 261 | 235 | 214 | 196 | 168 | 147 | ||
| CT 110.04 | ![]() |
2 | 1,31 | 196 | 174 | 157 | 142 | 131 | 112 | 98 |
| 3 | 1,60 | 240 | 213 | 192 | 174 | 160 | 137 | 120 | ||
| 4 | 1,85 | 277 | 247 | 222 | 202 | 185 | 158 | 139 | ||
| 5 | 2,07 | 310 | 275 | 248 | 225 | 207 | 177 | 155 | ||
| 6 | 2,26 | 339 | 302 | 272 | 247 | 226 | 194 | 170 | ||
| 7 | 2,44 | 367 | 326 | 293 | 267 | 244 | 209 | 183 | ||
| 8 | 2,61 | 392 | 348 | 314 | 285 | 261 | 224 | 196 | ||
| CT 110.08 | ![]() |
2 | 2,61 | 392 | 348 | 314 | 285 | 261 | 224 | 196 |
| 3 | 3,20 | 480 | 427 | 384,0 | 349 | 320 | 274 | 240 | ||
| 4 | 3,70 | 554 | 493 | 443 | 403 | 370 | 317 | 277 | ||
| 5 | 4,13 | 620 | 551 | 496 | 451 | 413 | 354 | 310 | ||
| 6 | 4,53 | 679 | 603 | 543 | 494 | 453 | 388 | 339 | ||
| 7 | 4,89 | 733 | 652 | 587 | 532 | 489 | 419 | 367 | ||
| 8 | 5,23 | 784 | 697 | 627 | 570 | 523 | 448 | 392 | ||
| TP 110.03 | ![]() |
2 | 0,98 | 147 | 131 | 118 | 107 | 98 | 84 | 73 |
| 3 | 1,20 | 180 | 160 | 144 | 131 | 120 | 103 | 90 | ||
| 4 | 1,39 | 208 | 185 | 166 | 151 | 139 | 119 | 104 | ||
| 5 | 1,55 | 232 | 207 | 186 | 169 | 155 | 133 | 116 | ||
| 6 | 1,70 | 255 | 226 | 204 | 185 | 170 | 145 | 127 | ||
| 7 | 1,83 | 275 | 244 | 220 | 200 | 183 | 157 | 137 | ||
| 8 | 1,96 | 294 | 261 | 235 | 214 | 196 | 168 | 147 |
Understanding nozzle markings: in CT 110.03, the letters identify the series, 110 is the nominal spray angle in degrees and 03 is the flow-rate size code. Actual flow rates at different pressures are given in the table.
Nozzle Characteristics and Applications
When selecting a nozzle, consider the type of treatment, spray liquid flow rate and droplet size. For comparison, the following data are given at the same pressure of 3 bar (0.3 MPa).
| Model | MMD*, µm | Droplet size | Recommended application |
|---|---|---|---|
| CT 110.03 | 240 | Fine / medium | Insecticides and fungicides |
| CT 110.04 | 270 | Medium | Herbicides |
| CT 110.08 | 310 | Coarse | Liquid mineral fertilisers, including UAN solutions, and soil-applied herbicides |
| TP 110.03 | ≈425 | Coarse, air-filled droplets | Applications requiring fewer fine droplets and reduced spray drift; select in accordance with the product label |
*MMD — mass median diameter: half of the sprayed liquid mass is contained in droplets smaller than this diameter, and the other half in larger droplets.
Select the nozzle and operating pressure in accordance with the sprayer operating manual and the instructions for the product being applied.
Operating Principle and Benefits of TP Air-Induction Nozzles
The TP 110.03 nozzle consists of two main components: a body and an air injector. Spray liquid passes through a calibrated orifice, creating a low-pressure zone that draws air through dedicated passages. The liquid mixes with air to form air-filled droplets, while the slot-shaped outlet produces a flat fan spray pattern with an angle of approximately 110°.
According to Remkom research, the number of droplets smaller than 100 µm is reduced by 90% compared with standard flat fan nozzles. This helps reduce the risk of spray drift.
Droplet size depends on operating pressure: the mass median diameter for the TP 110.03 nozzle is approximately 425 µm at 3 bar and 340 µm at 5 bar.
Air-filled droplets may adhere better to plant surfaces. However, treatment performance also depends on the spray product, application settings and weather conditions. Reduced drift does not override the wind-speed restrictions specified for the product being applied.
Remkom Nozzle Features
When the specified operating conditions are maintained, the following performance indicators meeting agronomic requirements are achieved:
- unevenness of spray liquid distribution across the boom width — no more than 15%;
- variation in flow rate between nozzles — no more than ±5%;
- droplet coverage density on the treated surface — at least 30 droplets/cm².
The performance of CT- and TP-series nozzles has been verified through bench tests conducted by Remkom LLC and tests carried out on Remkom sprayers at the Belarusian Machinery Testing Station (Belarusian MIS).
The nozzles are supplied in blister packs with flow-rate information.